Add to Cart
Transductor convexo del arsenal de Siemens C6-2
Otras puntas de prueba de Siemens que podemos ofrecer:
Marca | Modelo | Sistema compatible |
Siemens | 3.5C55S | G50/X150/X300 |
Siemens | 6C1HD | S2000 |
Siemens | 7.5L40A | G20/G40 |
Siemens | 7.5L75S | G20 y Prima/Adara |
Siemens | C7F2 | Antares/X300 y X.500 |
Siemens | CH4-1 | Antares |
Siemens | CH5-2 | G40/G60/X150/X300 |
Siemens | CH6-2 | Antares |
Siemens | CX5-2 | Antares/Sonoline Elegra |
Siemens | C6-2 | CV70/G50/G60/X300/X.500 |
Siemens | C6F3 | G50/G60 |
Siemens | C5F1 | Antares |
Siemens | C8-5 | X300 |
Siemens | P10-4 | Antares |
Siemens | PH4-1 | Antares |
Siemens | P4-2 | G50/G60/CV70/X150/X300/X500 |
Siemens | P5-1 | X300, X300PE |
Siemens | EC9-4 | G40/ X150/X300/Antares |
Siemens | EV9F4 | X300 y Antares |
Siemens | VFX9-4 | Antares |
Siemens | VF13-5sp | Antares/X300/X500/G50/G60 |
Siemens | VFX13-5 | Antares |
Siemens | VF13-5 | X150/X300/X500/G40 /G50/G60/ Tierra de Siena de Sonoline/Sonoline Elegra |
Siemens | VF13-5 | Antares |
Siemens | VF10-5 | Antares |
Siemens | 4V1C | Secoya 512 SOLDADOS ENROLLADOS EN EL EJÉRCITO, secoya C512, S2000 |
Siemens/Acuson | 4V1 | Secoya |
Siemens/Acuson | 6L3 | Secoya de Acuson |
Siemens/Acuson | 8C4 | Secoya 512 G /Sequoia C512 |
Siemens/Acuson | 8L5 | Secoya 512 |
Siemens/Acuson | 8V5 | Secoya |
Siemens/Acuson | 7L3 | Cypress |
Siemens/Acuson | 8V3 | Secoya 512 /S1000 |
Siemens/Acuson | 9EVF4 | S1000/ S2000 y S3000 |
Siemens/Acuson | 9L4 | Secoya de Acuson S2000//secoya C512 |
Siemens/Acuson | 10V4 | Secoya |
Siemens/Acuson | 15L8W | Secoya 512 |
Siemens/Acuson | 1518 | Secoya |
Siemens/Acuson | 17L5HD | Secoya 512 |
Siemens/Acuson | 18L6HD | S1000, S2000, S3000 |
Siemens/Acuson | CW AUX. | Sistema del CV de Cypress/de Cypress |
Siemens/Acuson | C3 | Aspen |
Siemens/Acuson | EC9-4 | G40/ G60/X150/X300 |
Siemens/Acuson | EC7 | Aspen XP128 |
Siemens/Acuson | EV-8C4 | Secoya 512/S2000 |
Siemens/Acuson | EC-10C5 | Secoya 512 |
Siemens/Acuson | L5 | Aspen |
Siemens/Acuson | L7 | Aspen/128XP-10 |
Siemens/Acuson | TE-V5M | Secoya C512/secoya 512/Aspen Cypress/S1000/S2000 de la secoya |
Siemens/Acuson | TE-V5Ms | Sistemas Cypress/Sequoia/S2000/X300 |
Siemens/Acuson | V4 | Aspen XP |
Siemens/Acuson | V7 | Aspen XP |
Punto del conocimiento
Punta de prueba anular
El principio de usar el método de concentración dividido en segmentos dinámico del arsenal circular del anillo en el equipo de diagnóstico ultrasónico de la sector-exploración mecánica es lo mismo que el de la concentración de la dinámica del arsenal linear. La aplicación de un retraso apropiado a la señal eléctrica de cada elemento puede alcanzar la concentración en cualquier distancia a lo largo del eje central, que es similar a la función de una lente acústica, así que funciona como de “lente concentración electrónica”.