China Categories
English
Home /Pressure Measuring Instruments /

4 Phase AC Protection Relay Testing , 10 Output Channels K3063i

4 Phase AC Protection Relay Testing , 10 Output Channels K3063i

Brand Name:Kingsine
Certification:ISO9001,CE
Model Number:K3063i
Minimum Order Quantity:1 set
Delivery Time:15 working days
Payment Terms:T/T in advance ,L/C
Contact Now

Add to Cart

Verified Supplier
Location: Shenzhen Guangdong
Address: 6/F, Block 4-CD, TianAn Cyber Park, Futian District, Shenzhen 518048,.China
Supplier`s last login times: within 1 hours
Shipping
lt's easy to get a shipping quote! Just click the button below and complete the short form.
Get Shipping Quote
Product Details Company Profile
Product Details

4-Phase AC Protection Relay Testing , 10 Output Channels K3063i


Relay protection test devices
1. Easy test
2. Operation menu, Simple operation
3. Nominal input voltage:220VAC
4. Power:1000VA

1. Unique self-protection system assure the powerful protection when instrument is operating, automatic

stop the output when the network is abnormal ;
2. Unique power switch and amplifier technology, so the output precision and power efficiency and factor

are increased, which conforms to international tendency of energy save and environmental protection;
3. With alarm function of housing grounding testing and external voltage input, to guaranty personal

security;
4. Two in one of meter and source, with function of both internal and external testing, self-calibration,

oscillograph, and the duration of each oscillograph reaches 50S (optional function);
5. Offer independent Aux. DC to tested devices, 0 ~ 300V/0.6A (Poleless and adjustable);
6. Function of transducer and energy meter testing (optional function);
7. Testing interface offer unique output monitoring function and Pre-curve-tracing function, helps more on

the spot analysis;

Technical Data of K3063i


Voltage generators

Setting

Range

4-phase AC (L-N)

4 x 0 ... 300 V

2-phase AC (L-L)

2 x 0 ... 600 V

Power

4-phase AC (L-N)

4 x 110VA, at 0 ... 300 V

2-phase AC (L-L)

2 x 220VA, at 0 ... 600 V

Accuracy

<0.07% reading + 0.03% range guaranteed at 0 ... 300 V

<0.02% reading + 0.01% range typical at 0-300V

Resolution

1mV

Current generators

Setting

Range

6-phase AC (L-N)

6 x 0 ... 30 A

3-phase AC (L-N)

3 x 0 ... 60 A (Group A II B)

1-phase AC (3L-N)

1 x 0 ... 180 A

Power

6-phase AC (L-N)

6x 450VA , at 0 ... 30A

3-phase AC (L-N)

3x 520VA, at 0 ... 60A (Group A II B)

1-phase AC (3L-N)

1 x 1000 VA, at 0 ... 180A (Max.)

Accuracy

<0.07% reading + 0.06% range guaranteed at 0-30A

<0.02% reading + 0.02% range typical at 0-30A

Resolution

1mA

Generators, general

Frequency

Range

0 ... 1000 Hz

Accuracy / drift

Error < 0.001Hz at 10 ... 65Hz,

Error < 0.01Hz at 65Hz...450Hz

Error < 0.02Hz at 450Hz...1000Hz

Resolution

0.001Hz

Phase

Range

- 360° ... +360°

Accuracy / drift

Error < 0.2 °

Resolution

0.1°

Timer

Range

Infinite

Accuracy / drift

Error<0.1ms

DC generators

Voltage ranges

0 ... 300V/180W

Current ranges

0 ... 20A/300W

Accuracy

<0.07% reading + 0.03% range guaranteed at 0-300V

<0.04% reading + 0.02% range typical at 0-300V

<0.14% reading + 0.06% range guaranteed at 0-20A

<0.05% reading + 0.02% range typical at 0-20A

Resolution

1mA; 1 mV

Aux DC Supply

Range

0...300V/0.6A

Binary inputs

Number

8 pairs

Compatible Voltage

10V ... 250V DC

Binary outputs

Number

4 Pairs

Capacity

250V/3A AC/DC

Synchronization

Synchronization mode

GPS

Harmonic

Harmonic overlap times

2 ... 20 times

Power supply

Nominal input voltage

220VAC±20%

Power

1000VA

Nominal frequency

47Hz….65Hz

Environmental conditions

Operation temperature

-5°C ... 55 °C

Storage temperature

-20°C ... 75 °C

Humidity range

5% ... 90 %, non-condensing

Weight

20 KG

Dimensions

460(D)×140 (W)×360 (H) mm

PC connection

RJ45

K30 Series Protection Relay Test Set:


Model

Channels

AC Outputs

K3063i / K3063Li

10 output channels

6*30A/3*40A/4*300V

K3030i / K3030Li

7 output channels

3*30A/4*300V

K3066

13 output channels

6*20A/3*40A/7*130V

K3063

10 output channels

6*20A/3*40A/4*130V

K3040

7 output channels

3*40A/4*130V

K3030

7 output channels

3*30A/4*130V


Major Functions:


Items

IEEE(R) No.

Synchronization relay

Fault transplay

GPS Synchronization

Overcurrent relays

50/76

Inverse time overcurrent relays

51

Undercurrent relays

37

Ground fault relays

50

Directional overcurrent relays

67

Directional ground fault relays

67N

Overvoltage relays

59

Undervoltage relays

27

Directional voltage relays

91

Directional power relays

32

Power factor relays

55

Differential protection (differential circuits)

87

Distance protection equipment (phase by phase)

21

Negative sequence overcurrent relays

46N

Motor overload protection

51/86

Automatic reclosing devices

79

Tripping relays

94

Voltage regulating relays

Overimpedance relays, Z>

Underimpedance relays, Z

Time-delay relays


China 4 Phase AC Protection Relay Testing , 10 Output Channels K3063i supplier

4 Phase AC Protection Relay Testing , 10 Output Channels K3063i

Inquiry Cart 0